|
|
Registro Completo |
Biblioteca(s): |
Embrapa Unidades Centrais. |
Data corrente: |
29/05/2018 |
Data da última atualização: |
29/05/2018 |
Autoria: |
SILVA, E. G.; PESSOA, G. T.; MOURA, L. S.; GUERRA, P. C.; RODRIGUES, R. P. S.; SOUSA, F. C. A.; AMBRÓSIO, C. E.; ALVES, F. R. |
Afiliação: |
Elzivânia G. Silva, Pós-Graduação em Ciência Animal/Universidade Federal do Piauí - UFPI; Gerson T. Pessoa, Serviço de Diagnóstico por Imagem do Hospital Veterinário Universitário/UFPI; Laecio S. Moura, Pós-Graduação em Ciência Animal/Universidade Federal do Piauí - UFPI; Porfírio C. Guerra, Departamento das Clínicas/Universidade Estadual do Maranhão - UEMA; Renan P. S. Rodrigues, Pós-Graduação em Ciência Animal/Universidade Federal do Piauí - UFPI; Francisco C. A. Sousa, Departamento de Medicina/Universidade Estadual do Piauí - UESPI; Carlos E. Ambrósio, Departamento de Medicina Veterinária/Universidade de São Paulo - USP; Flávio R. Alves, Departamento de Morfofisiologia Veterinária/UFPI. |
Título: |
Biometric, B-mode and color Doppler ultrasound assessment of eyes in healthy dogs. |
Ano de publicação: |
2018 |
Fonte/Imprenta: |
Pesquisa Veterinária Brasileira, Rio de Janeiro, v. 38, n. 3, p. 565-571, março, 2018 |
Idioma: |
Inglês |
Notas: |
Título em português: Avaliação biométrica, ultrassonográfica em modo-B e por Doppler colorido ocular de cães hígidos. |
Conteúdo: |
B-scan ultrasonography is an important diagnostic tool that allows characterization of internal organ anatomy and, when complemented by Doppler ultrasound, allows vascular hemodynamic assessment, increasing the diagnostic accuracy. Thus, the aim of the present study was the B-scan ultrasound characterization and measurement of the eyeball segments and assessment of the external ophthalmic artery by color and pulsed Doppler. Sixty eyeballs were assessed from 30 dogs of different breeds using an 8.5MHz microconvex transductor. First, biometry was performed by B-scan of the following segments: axial length (M1), anterior chamber depth (M2), lens thickness (M3), lens length (M4), vitreous chamber depth (M5), optical disc length (M6) and optic nerve diameter (M7). Colored Doppler identified the external ophthalmic article and pulsed Doppler assessed its flow, and the following were measured: systolic peak velocity (VPS), final diastolic velocity (VDF), resistivity index (IR) and pulse index (IP). No statistical difference was observed for the biometric values of the eye segments between the right and left eyes (p>0.05). The vitreous chamber depth (M5) was shown to be the biometric variable with greatest bilateral symmetry, varying from 0.79 to 0.87cm and 0.78 to 0.86cm for the right and left ye, respectively. The ophthalmic artery was visualized over the optic nerve towards the eyeball, with flow stained red. There was no significant statistical difference between the Doppler velocimetric values for the ophthalmic artery between the right and left eye of the animals assessed (p>0.05). The mean resistivity index (RI) showed average values equal to 0.63±0.03, bilaterally. The mean base velocity was 17.50cm/s and 18.18cm/s at the systolic peak and 6.21cm/s and 6.68cm/s at the end of the diastole, for the right and left eyes respectively. The anatomic, biometric and hemodynamic characterization using the ultrasound B-scan and the Doppler modalities permitted the ultrasonographic and Doppler velocimetric assessment of the eyeball components in dogs of different breeds, and it can be used in ophthalmic clinical routine to identify eye pathologies. MenosB-scan ultrasonography is an important diagnostic tool that allows characterization of internal organ anatomy and, when complemented by Doppler ultrasound, allows vascular hemodynamic assessment, increasing the diagnostic accuracy. Thus, the aim of the present study was the B-scan ultrasound characterization and measurement of the eyeball segments and assessment of the external ophthalmic artery by color and pulsed Doppler. Sixty eyeballs were assessed from 30 dogs of different breeds using an 8.5MHz microconvex transductor. First, biometry was performed by B-scan of the following segments: axial length (M1), anterior chamber depth (M2), lens thickness (M3), lens length (M4), vitreous chamber depth (M5), optical disc length (M6) and optic nerve diameter (M7). Colored Doppler identified the external ophthalmic article and pulsed Doppler assessed its flow, and the following were measured: systolic peak velocity (VPS), final diastolic velocity (VDF), resistivity index (IR) and pulse index (IP). No statistical difference was observed for the biometric values of the eye segments between the right and left eyes (p>0.05). The vitreous chamber depth (M5) was shown to be the biometric variable with greatest bilateral symmetry, varying from 0.79 to 0.87cm and 0.78 to 0.86cm for the right and left ye, respectively. The ophthalmic artery was visualized over the optic nerve towards the eyeball, with flow stained red. There was no significant statistical difference between the Doppler vel... Mostrar Tudo |
Palavras-Chave: |
B-mode; Bulbo ocular; Cão hígido; Doppler colorido ocular; Doppler ultrasound; Doppler velocimetry; Dopplervelocimetria; Eyeball; Ultrassonografia. |
Thesagro: |
Biometria; Cão. |
Thesaurus Nal: |
Biometry; Dogs; Hemodynamics; Ophthalmology. |
Categoria do assunto: |
-- |
URL: |
https://ainfo.cnptia.embrapa.br/digital/bitstream/item/177793/1/Biometric-B-mode-and-color-Doppler-ultrasound.pdf
|
Marc: |
LEADER 03392naa a2200397 a 4500 001 2092022 005 2018-05-29 008 2018 bl uuuu u00u1 u #d 100 1 $aSILVA, E. G. 245 $aBiometric, B-mode and color Doppler ultrasound assessment of eyes in healthy dogs.$h[electronic resource] 260 $c2018 500 $aTítulo em português: Avaliação biométrica, ultrassonográfica em modo-B e por Doppler colorido ocular de cães hígidos. 520 $aB-scan ultrasonography is an important diagnostic tool that allows characterization of internal organ anatomy and, when complemented by Doppler ultrasound, allows vascular hemodynamic assessment, increasing the diagnostic accuracy. Thus, the aim of the present study was the B-scan ultrasound characterization and measurement of the eyeball segments and assessment of the external ophthalmic artery by color and pulsed Doppler. Sixty eyeballs were assessed from 30 dogs of different breeds using an 8.5MHz microconvex transductor. First, biometry was performed by B-scan of the following segments: axial length (M1), anterior chamber depth (M2), lens thickness (M3), lens length (M4), vitreous chamber depth (M5), optical disc length (M6) and optic nerve diameter (M7). Colored Doppler identified the external ophthalmic article and pulsed Doppler assessed its flow, and the following were measured: systolic peak velocity (VPS), final diastolic velocity (VDF), resistivity index (IR) and pulse index (IP). No statistical difference was observed for the biometric values of the eye segments between the right and left eyes (p>0.05). The vitreous chamber depth (M5) was shown to be the biometric variable with greatest bilateral symmetry, varying from 0.79 to 0.87cm and 0.78 to 0.86cm for the right and left ye, respectively. The ophthalmic artery was visualized over the optic nerve towards the eyeball, with flow stained red. There was no significant statistical difference between the Doppler velocimetric values for the ophthalmic artery between the right and left eye of the animals assessed (p>0.05). The mean resistivity index (RI) showed average values equal to 0.63±0.03, bilaterally. The mean base velocity was 17.50cm/s and 18.18cm/s at the systolic peak and 6.21cm/s and 6.68cm/s at the end of the diastole, for the right and left eyes respectively. The anatomic, biometric and hemodynamic characterization using the ultrasound B-scan and the Doppler modalities permitted the ultrasonographic and Doppler velocimetric assessment of the eyeball components in dogs of different breeds, and it can be used in ophthalmic clinical routine to identify eye pathologies. 650 $aBiometry 650 $aDogs 650 $aHemodynamics 650 $aOphthalmology 650 $aBiometria 650 $aCão 653 $aB-mode 653 $aBulbo ocular 653 $aCão hígido 653 $aDoppler colorido ocular 653 $aDoppler ultrasound 653 $aDoppler velocimetry 653 $aDopplervelocimetria 653 $aEyeball 653 $aUltrassonografia 700 1 $aPESSOA, G. T. 700 1 $aMOURA, L. S. 700 1 $aGUERRA, P. C. 700 1 $aRODRIGUES, R. P. S. 700 1 $aSOUSA, F. C. A. 700 1 $aAMBRÓSIO, C. E. 700 1 $aALVES, F. R. 773 $tPesquisa Veterinária Brasileira, Rio de Janeiro$gv. 38, n. 3, p. 565-571, março, 2018
Download
Esconder MarcMostrar Marc Completo |
Registro original: |
Embrapa Unidades Centrais (AI-SEDE) |
|
Biblioteca |
ID |
Origem |
Tipo/Formato |
Classificação |
Cutter |
Registro |
Volume |
Status |
URL |
Voltar
|
|
Registros recuperados : 7 | |
2. | | DIONISIO, L. F. S.; AUCA, E. C.; BARDALES-LOZANO, R. M.; SCHWARTZ, G.; RODRIGUES. R. P.; CORVERA-GOMRINGER, R. Production of Bertholletia excelsa Humb. & Bonpl., (Lecythidaceae) seedlings in microenvironments under different substrates. Revista Brasileira de Ciências Agrárias, v. 14, n. 3, e5847, 2019.Tipo: Artigo em Periódico Indexado | Circulação/Nível: B - 1 |
Biblioteca(s): Embrapa Amazônia Oriental. |
| |
3. | | RODRIGUES, R. P.; GONÇALVES, D. de A.; SILVA, A. R.; MARTINS, W. B. R.; DIONISIO, L. F. S.; SCHWARTZ, G. Crescimento e mortalidade de Tachigali vulgaris L.G.Silva & H.C.Lima em diferentes espaçamentos de plantio para a produção de biomassa. Scientia Forestalis, v. 48, n. 128, e3269, 2020.Tipo: Artigo em Periódico Indexado | Circulação/Nível: B - 1 |
Biblioteca(s): Embrapa Amazônia Oriental. |
| |
4. | | PESSOA, G. T.; SOUSA, F. C. A.; RODRIGUES, R. P. S.; MOURA, L. S.; SANCHES, M. P.; AMBRÓSIO, C. E.; SILVA, A. B. S.; ALVES, F. R. Abdominal B-mode and Doppler ultrasonography of chemically restrained agouti (Dasyprocta prymnolopha Wagler, 1831). Pesquisa Veterinária Brasileira, Rio de Janeiro, v. 38, n. 4, p. 785-793, abril 2018 Título em português: Ultrassonografia abdominal em Modo B e Doppler de cutias (Dasyprocta prymnolopha Wagler, 1831) contidas quimicamente.Biblioteca(s): Embrapa Unidades Centrais. |
| |
5. | | SILVA-FILHO, O. F.; PESSOA, G. T.; SOUSA, F. C. A.; RODRIGUES, R. P. S.; MOURA, L. S.; AMBRÓSIO, C. E.; SILVA, A. B. S.; ALVES, F. R. Assessment of the vertebral heart scale and cardiothoracic ratio to standardize the heart size of collared peccaries (Tayassu tajacu Linnaeus, 1758) restrained with ketamine and midazolam. Pesquisa Veterinária Brasileira, Brasília, DF, v. 38, n 8, p. 1705-1711, agosto 2018 Título em português: Avaliação do vertebral heart scale e índice cardiotorácico na padronização do tamanho cardíaco de cateto (Tayassu tajacu Linnaeus, 1758) contidos com cetamina e midazolam.Biblioteca(s): Embrapa Unidades Centrais. |
| |
6. | | SILVA, E. G.; PESSOA, G. T.; MOURA, L. S.; GUERRA, P. C.; RODRIGUES, R. P. S.; SOUSA, F. C. A.; AMBRÓSIO, C. E.; ALVES, F. R. Biometric, B-mode and color Doppler ultrasound assessment of eyes in healthy dogs. Pesquisa Veterinária Brasileira, Rio de Janeiro, v. 38, n. 3, p. 565-571, março, 2018 Título em português: Avaliação biométrica, ultrassonográfica em modo-B e por Doppler colorido ocular de cães hígidos.Biblioteca(s): Embrapa Unidades Centrais. |
| |
7. | | ROCHA-NETO, H. J.; MOURA, L. da S.; PESSOA, G. T.; AMBRÓSIO, C. E.; SOUSA, F. C. A.; RODRIGUES, R. P. S.; GUERRA, P. C.; ALVES, F. R. Cardiothoracic ratio and vertebral heart size (VHS) to standardize the heart size of the tufted capuchin (Cebus apella Linnaeus, 1758) in computerized radiographic images. Pesquisa Veterinária Brasileira, Brasília, DF, v. 35, n. 10, p. 853-858, out. 2015.Biblioteca(s): Embrapa Unidades Centrais. |
| |
Registros recuperados : 7 | |
|
Nenhum registro encontrado para a expressão de busca informada. |
|
|